Test-rig data your team can inspect and compare.
Build run-setup screens around your rig's tags, record configured signals in PostgreSQL, and query history for analysis. Keep screen code, tag mappings, and transaction definitions in Git. Your rig controller and application define the test sequence and records.
- Test-run workflowsBuild run-setup and monitoring screens around your rig's tags. Use PostgreSQL transactions to capture parameters and results for your application.
- Real-time data acquisitionConnect your equipment through OPC UA client polling and writes, Modbus TCP, or S7comm TCP. Live tags carry quality and timestamps.
- History for analysisQuery timestamped raw or aggregated history over HTTP, then transform the results into the format your analysis tools require.
- Operator screensGive each rig its own screens and tag namespace for run setup, live monitoring, and post-run review.
- Application parametersAuthor screen controls for the parameters your controller exposes. Use tag writes to send values and database transactions to capture results.
What you can build with Thermite SCADA.
Build run-setup and monitoring screens around your rig's tags. Use PostgreSQL transactions to capture parameters and results for your application.
Connect your equipment through OPC UA client polling and writes, Modbus TCP, or S7comm TCP. Live tags carry quality and timestamps.
Query timestamped raw or aggregated history over HTTP, then transform the results into the format your analysis tools require.
Give each rig its own screens and tag namespace for run setup, live monitoring, and post-run review.
Author screen controls for the parameters your controller exposes. Use tag writes to send values and database transactions to capture results.
The source includes a flow-lab SCADA example and separate flow-bench and aerospace-fatigue device simulators.
How it fits your work.
Repeatable procedures
Version test configuration and analysis code so your team can repeat the procedure and compare measured results.
Quality propagates
Raw history preserves values, quality, and timestamps. Use those fields in your analysis; numeric aggregated queries use Good-quality samples.
Single license, unlimited rigs
One unlimited license covers every test cell, the plant lab, and the central historian — no per-server licensing, no edition split.
Related Thermite SCADA documentation.
Have a test rig or lab to model?
Bring your sensor list, test sequence, and result schema. We'll work through tag mappings, monitoring screens, and data capture.