Query your tag history as raw values or interval aggregates.
Thermite SCADA records configured tag changes in PostgreSQL. Choose per-tag sampling limits and deadbands in project files, then query typed raw values or numeric interval aggregates over HTTP. Historian is included in the platform license.
- Tag history recordingPer-tag on-change recording, minimum intervals between recorded changes, and absolute or percentage deadbands.
- Recording controlsSet recording limits and deadbands independently of device polling rates. Keep history settings alongside the tag definition in TOML.
- Aggregated queriesAverage, minimum, maximum, count, first, and last numeric values over explicit query intervals for dashboards and analysis.
- Pending sample bufferPending samples use a bounded memory buffer during database interruptions. New samples replace the oldest when the buffer fills.
- PostgreSQL storageRecord tag history in the configured PostgreSQL database, with project and tag identity attached to stored samples.
What you can build with Thermite SCADA.
Per-tag on-change recording, minimum intervals between recorded changes, and absolute or percentage deadbands.
Set recording limits and deadbands independently of device polling rates. Keep history settings alongside the tag definition in TOML.
Average, minimum, maximum, count, first, and last numeric values over explicit query intervals for dashboards and analysis.
Pending samples use a bounded memory buffer during database interruptions. New samples replace the oldest when the buffer fills.
Record tag history in the configured PostgreSQL database, with project and tag identity attached to stored samples.
Stream live tags over WebSocket and query history over HTTP. With authentication on, project roles control history access.
How it fits your work.
Historian is included
No separately licensed historian module, no edition limit on history rows, no surprise add-on fees.
Quality propagates
Raw history preserves quality and timestamps. Numeric aggregated queries use Good-quality samples; your analysis code can check quality on raw points.
Edge-friendly
The same gateway runtime records to a configured PostgreSQL database from an edge host or plant server.
Reviewable recording settings
History enablement, sampling limits, and deadbands live in tag TOML files. Review these settings in Git with the rest of the project.